SPECIFICATIONS(TEC103)

PARAMETERS

MODEL

UNIT

TEC103L

TEC103

24-hour Temperature Measurement Stability

(with the matched thermistor)

<0.001@20℃

<0.001@20℃

Temperature drift caused by ambient temperature

0.0001

0.0001

℃/℃

Optimal Temperature Control Stability

(related to the overall system)

±0.01

±0.001

°C

Temperature Change Limit Setting Range

0.1~10

0.1~10

℃/s

Temperature Setting Method

UART

UART

 

Power Supply Voltage

(Short-term Maximum Voltage: 28V)

7~24

7~24

V

Output Polarity

Bipolar、Unipolar

Bipolar、Unipolar

V

Number of Temperature Control Zones

1

1

 

Maximum Output Voltage

±90%Vin (Settable)

±90%Vin (Settable)

 

Rated Current@24V

±3

±3

A

Ambient Temperature

-55~60

-55~60

°C

Ambient Humidity

0-98

0-98

%RH

Thermal Dissipation Requirements

No Additional Thermal Dissipation Needed Within Rated Operating Range

No Additional Thermal Dissipation Needed Within Rated Operating Range

 

Circuit Board Overheat Protection

Yes

Yes

 

Power Loss Memory

Yes

Yes

 

PID Parameters

User Adjustable

User Adjustable

 

Size

46.5*39.0*9.6

46.5*39.0*9.6

mm³

Weight

≈30

≈30

g

Dimensional Drawing

Interfaces

Pin Number

Pin Name

Pin Type

Pin Definition (High Level: 3.3V, Low Level: 0V)

1

GND

Input

Power Input Negative Pole (Low Current).

2

STATE

Output

Temperature Control Status Output. High Level: Temperature control is functioning normally (temperature control error < 0.01°C). Low Level: Temperature control anomaly detected (temperature control error ≥ 0.01°C). The temperature control standard of 0.01°C can be set.

3

ENABLE

Input

Output Enable Pin. High Level (Default): Enables temperature control output. Low Level: Disables temperature control output.

4

TX2

Output

Serial Port 2 Receiver, TTL Level, used for connecting to the Screen Display Control Module.

5

RX2

Input

Serial Port 2 Receiver, TTL Level, used for connecting to the Screen Display Control Module.

6

VCC

Output

3.3V Output, intended for connection to the screen display control module and not recommended for other uses.

7

TX1

Output

Serial Port 1 Receive End, TTL level, used for connecting to PC control software. Data bits: 8 bits, Stop bits: 1 bit, Parity: None, Baud Rate: 38400.

8

RX1

Input

Serial Port 1 Receive End, TTL level, used for connecting to PC control software. Data bits: 8 bits, Stop bits: 1 bit, Parity: None, Baud Rate: 38400.

9

NTC-

Input

Thermistor (NTC) Interface, compatible with different resistance values of NTC thermistors, with wiring polarity not required.

10

NTC+

Input

Thermistor (NTC) Interface, compatible with different resistance values of NTC thermistors, with wiring polarity not required.

11

GND

Input

Power Input Negative Pole (High Current).

12

GND

Input

Power Input Negative Pole (High Current).

13

Vin

Input

Power Input Positive Pole, with an input voltage range of 7 to 24V.

14

Vin

Input

Power Input Positive Pole, with an input voltage range of 7 to 24V.

15

TEC-

Output

The negative terminal of the temperature control current output is usually connected to the negative terminal of the Thermoelectric Cooler (TEC).

16

TEC-

Output

The negative terminal of the temperature control current output is usually connected to the negative terminal of the Thermoelectric Cooler (TEC).

17

TEC+

Output

The positive terminal of the temperature control current output is typically connected to the positive terminal of the Thermoelectric Cooler (TEC).

18

TEC+

Output

The positive terminal of the temperature control current output is typically connected to the positive terminal of the Thermoelectric Cooler (TEC).

Evaluation Board

Image with text

Pair large text with an image to tell a story, explain a detail about your product, or describe a new promotion.