(function(){
let w = window.innerWidth;
function setHeaderCssVar() {
const headerEle = document.getElementById('shoplaza-section-header');
if(!headerEle){ return };
document.body.style.setProperty('--window-height', `${window.innerHeight}px`);
document.body.style.setProperty('--header-height', `${headerEle.clientHeight}px`);
const mdScorllHideEle = headerEle.querySelector('.header__mobile .header__scroll_hide');
if (mdScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-md', `${mdScorllHideEle.clientHeight}px`);
}
const pcScorllHideEle = headerEle.querySelector('.header__desktop .header__scroll_hide');
if (pcScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-pc', `${pcScorllHideEle.clientHeight}px`);
}
}
function handlResize() {
if(w == window.innerWidth){return};
w = window.innerWidth;
setHeaderCssVar();
};
function init(){
setHeaderCssVar();
window.removeEventListener('resize', window._theme_header_listener)
window._theme_header_listener = handlResize;
window.addEventListener('resize', window._theme_header_listener);
}
init();
})();
1/1
${data.index + 1}/${data.total}
Description
The TEB is designed to provide scientific research clients and enterprise customers with a highly accurate and stable temperature environment (±0.005°C) during the product development phase. Clients can place temperature-sensitive optical components, circuit boards, sample chambers, sensors, or even entire instruments within this precision incubator to enhance experimental outcomes and analyze the extent of temperature effects on their parts and components.
1. User-friendly operation with plug-and-play functionality and the ability to connect to computer display software.
2. The foam-insulated temperature chamber allows users to freely cut openings (a hole-cutting auxiliary tool is provided).
3. Offers high temperature control precision with a typical control stability of ±0.005°C.
4. Wide temperature setting range, adjustable from -12°C below ambient temperature to +25°C above ambient temperature.
5. Giving away computer software.
SPECIFICATIONS
PARAMETERS
NUMBER
UNIT
MINIMUM
TYPICAL
MAXIMUM
24-hour Temperature Control Stability
±0.005@30℃
±0.01
℃
Temperature Setting Range
Ambient Temperature-12
/
Ambient Temperature+25
℃
Material
High-Quality Foamed Polypropylene
Internal Temperature Gradient
——
℃
Internal Air Temperature Stability
±0.02@30℃
℃
Instrument Power Requirements
AC 220
V
Instrument Power Consumption
<102
W
Ambient Temperature Range
-15
Room temperature
60
°C
Ambient Humidity
0
(In high humidity environments during cooling, condensation may form on the internal cooling fins)